Iei 2002 keypad manual4/8/2024 The wire colors are shown in the table below. Output Relay Connector Alarm Shunt K2 P1 Propped Door K3 P2 Forced Door K4 P3 Use the wire harnesses supplied with the relay board to connect to the relays. IEI 232e Standalone Installation/Programming Manual 4.6 Installing the Plug-On Relay Board The Plug-On relay board contains the alarm shunt, propped door, and forced door relays. Connect the white/orange (loop common) to the common on the REX device and the common the door switch. Connect the brown wire (REX Input) to the normally open connection the REX device. IEI 232e Standalone Installation/Programming Manual 4.5 Wiring Remote Trigger as Request to Exit (REX) Button and Door Contacts Use the following steps to connect the 232e keypad to a normally open REX device and normally closed door switch: 1. Figure 7 Shunting a Normally Closed Zone Document # 6054004, Rev. Connect the green wire (normally open) to the normally closed connection on the door position switch. Connect the blue wire (common) to the common connection on the door position switch. IEI 232e Standalone Installation/Programming Manual Figure 6 Wiring 232e Keypad to Electric Strike 4.4 Shunting a Normally Closed Zone Use the following steps to employ the 232e keypad to shunt a normally closed zone: 1. Connect the black wire (V-) to the negative on the Maglock, and then connect them to the negative on the power supply. Connect the gray wire (normally closed) to the positive on the maglock. Connect the red wire (V+) to the blue wire (common), and then connect them to the positive on the power supply. IEI 232e Standalone Installation/Programming Manual 4.2 Wiring the 232e Keypad to a Maglock (FailSafe) Use the following steps to connect the 232e keypad to a Maglock (Fail-Safe): 1. Wiring Figure 4 232e Connector and Wire Harness 4. IEI 232e Standalone Installation/Programming Manual 4. Mounting height can vary depending on requirements. To properly size the mounting and wire access hole, use the installation template on the last page of this manual and on the unit’s container. In addition, it can be flush mounted directly to the wall surface by cutting a hole in the wall. Mounting The keypad is designed to be flush mounted using a standard singlegang electrical box. IEI 232e Standalone Installation/Programming Manual 3. IEI 232e Standalone Installation/Programming Manual Figure 1 Mounting a Sentrol 3012 Tamper Switch Figure 2 Mounting a Sentrol 3025T Tamper Switch Document # 6054004, Rev. In addition, all wires and cables used must be stranded and shielded U.L. This system must be installed in accordance with the National Electrical code (NFPA70), local codes, and the authorities having jurisdiction. This section contains information regarding all the requirements necessary to meet U.L. IEI 232e Standalone Installation/Programming Manual Section 3. Specifications Parameter Range/Description Voltage 10-30 VDC, 12-24 VAC Current and Add 20 mA for each alarm relay Environment Indoor and Outdoor Temperature Tolerance -20 ☏ to 130 ☏ Dimensions 4.5" H x 2.75" W x 0.60" D Main Relay (Form C) Alarm Relays: Alarm Shunt, Propped Door, Forced Door Relays (Form C) Document # 6054004, Rev. IEI 232e Standalone Installation/Programming Manual 2. IEI 232e Standalone Installation/Programming Manual 1. Requirements Specifications Mounting Wiring 5.1 Wire Harness Configuration 5.2 Wiring the 232e Keypad to a Maglock (Fail-Safe) 5.3 Wiring the 232e Keypad to an Electric Strike (Fail-Secure) 5.4 Shunting a Normally Closed Zone 5. IEI 232e StandaloneTM Keypad Installation/ Programming Manual Contents Section 1: Section 2: Section 3: Section 4: Section 5: Section 6: Section 7: Section 8: Section 9: Section 10: Features and Product Description 1.1 Features 1.2 Product Description U.L.
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |